1612 25 Ave SW semi-detached structural engineering design and P.Eng stamped permit drawings by Tam-Crete Engineering in Calgary, Alberta
Semi-Detached Structural Engineering APEGA P.Eng. Authenticated Lots 11 & 12, Blk 2, Plan 2714P

1612 25 Ave SW (Units 2518 & 2520) — 3-Story Semi-Detached Structural Design

Complete P.Eng. stamped structural engineering, stepped concrete foundation and retaining wall design, drive-under garage transfer beam analysis, and multi-story wood superstructure framing for a sloping residential infill in Southwest Calgary.

Project Location 1612 25 Ave SW, Calgary
Building Configuration Semi-Detached (2518 & 2520)
Total Living Area 4,165 sq.ft. + Dual Garages
Footprint & Height 41'-8" W × 10.94m Peak
Vertical Structure 3-Story + Walkout Basement
Governing Codes ABC / NBC (AE) & CSA

Project Overview & Structural Engineering Role

Located at 1612 25 Ave SW in Calgary (legally described as Lots 11 and 12, Block 2, Plan 2714P), this inner-city residential infill comprises two asymmetrical 3-story semi-detached homes—Unit 2518 (West/Left) and Unit 2520 (East/Right)—spanning an overall building width of 41'-8" (21'-10" and 19'-10" unit widths) and reaching a peak roof height of 10.94m (geodetic elevation 1104.38m).

Site Grading & Structural Design Challenges

The parcel presents a pronounced front-to-rear grade differential—rising from geodetic elevation 1091.80m at the front property line (garage slab at 1090.80m) up to 1093.95m at the rear yard, with main floor framing elevated to 1094.40m. Tam-Crete Engineering provided comprehensive residential structural engineering and P.Eng. stamped permit drawings to resolve the multi-level load paths and steep terrain retention.

Tam-Crete Engineering Core Deliverables:

  • Stepped Foundation & Retaining Wall Engineering: Custom reinforced concrete retaining walls, treated wood rear perimeter retaining walls, and cast-in-place exterior concrete stairs flanking the front driveways.
  • Drive-Under Garage Transfer Portals: High-load garage foundation slabs (with continuous floor trench drains) and narrow-wall lateral shear portals spanning twin 16'-0" × 8'-0" overhead garage doors supporting three full stories above.
  • 3-Story Wood Superstructure & Cantilevers: Vertical and lateral wind/seismic design for 9'-1" Basement, 9'-1" Main, 8'-1" Second, and 8'-1" Third floor levels, including rear decks and third-floor walkout balconies.
  • ABC 9.10.14.4 Spatial Separation Verification: Central party wall acoustic/fire separation and unprotected window opening calculations for tight 1.20m and 1.21m side limiting distances.
Structural Floor Area Schedule Units 2518 & 2520
Floor Level (Ceiling Height)Unit 2518 (Left)Unit 2520 (Right)Combined Total
Main Floor (9'-1" Clg)739 sq.ft.670 sq.ft.1,409 sq.ft.
Second Floor (8'-1" Clg)747 sq.ft.678 sq.ft.1,425 sq.ft.
Third Floor Loft (8'-1" Clg)304 sq.ft.547 sq.ft.851 sq.ft.
Above-Grade Subtotal1,790 sq.ft.1,895 sq.ft.3,685 sq.ft.
Dev. Basement (9'-0" Clg)209 sq.ft. + Garage271 sq.ft. + Garage480 sq.ft. + Garages
Total Living Area1,999 sq.ft.2,166 sq.ft.4,165 sq.ft.
Spatial Separation (ABC 9.10.14.4) Unprotected Openings
Building FaceWall AreaLimiting Dist.Actual vs. Max Allowed
Left Elevation (2518)893 sq.ft.1.21 m61.25 sq.ft. (6.8% ≤ 7% Max)
Right Elevation (2520)929 sq.ft.1.20 m56.00 sq.ft. (6.0% ≤ 7% Max)
Rear Elevation (Left)545 sq.ft.3.23 m42.00 sq.ft. (7.7% ≤ 8% Max)
Rear Elevation (Right)530 sq.ft.3.23 m53.00 sq.ft. (10.0% ≤ 10% Max)

Technical Engineering Scope & System Specifications

Engineered in strict compliance with the Alberta Building Code (ABC / NBC AE), CSA standards, and City of Calgary infill regulations.

01 / SUBSTRUCTURE

Stepped Foundations & Retaining Walls

Engineered reinforced concrete foundation walls (41'-8" × 40'-7" footprint), exterior concrete side retaining walls, treated wood retaining structures, and cast-in-place staircases transitioning from the 1090.80m garage level to the 1094.40m main floor.

02 / SUPERSTRUCTURE

Drive-Under Garage Portals & Framing

Heavy-duty transfer beams and lateral shear portal frames spanning twin 16'-0" × 8'-0" garage doors (20'-3" × 20'-3" left bay and 18'-3" × 20'-3" right bay with trench drains) supporting three stories of wood framing above.

03 / ROOF & DECKS

Engineered Trusses & Balcony Cantilevers

Asymmetrical 3/12 and 5/12 engineered roof truss systems reaching 1104.38m (Unit 2520) and 1103.36m (Unit 2518), plus structural framing for rear decks (21'-8"×5'-0" & 20'-0"×5'-0") and 3rd-floor walkout balconies.

04 / SEPARATIONS & CODE

Party Wall & Limiting Distance Design

Continuous fire-rated and acoustic central party wall separating Units 2518 & 2520, structural anchorage for 2.0m high privacy screens and glass/aluminum guardrails, and verified window openings per ABC 9.10.14.4.

Phase 1: 3-Story Superstructure, Roof Trusses & Drive-Under Garage Portals

Superstructure & Streetscape
Completed 3-story front elevation of Units 2518 and 2520 at 1612 25 Ave SW Calgary engineered by Tam-Crete Engineering
Asymmetrical 3-story front elevation showcasing 3/12 & 5/12 engineered roof trusses, central cultured stone party-wall pier, and third-floor walkout balconies.
Twin 16x8 drive-under garage structural portal frames and transfer beams at 1612 25 Ave SW Calgary by Tam-Crete Engineering
Streetscape perspective along 25 Ave SW highlighting twin 16'-0" × 8'-0" structural garage portal frames and sloped driveway aprons at elevation 1090.80m.
Multi-story wood framing, tall walls, and Longboard siding projections for Unit 2520 at 1612 25 Ave SW Calgary
Unit 2520 multi-story wood superstructure, upper-floor Longboard siding architectural projections, and flanking cast-in-place exterior entry stairs.

Phase 2: Stepped Concrete Foundations, Retaining Walls & Entry Framing

Substructure & Grade Retention
Stepped reinforced concrete retaining wall and elevated main floor porch framing at 1612 25 Ave SW Calgary
Unit 2520 stepped concrete retaining wall, elevated main-floor porch framing (1094.40m), and lower walkout basement access door.
High-wall reinforced concrete side retaining wall and lateral shear wall framing for Unit 2518 in Calgary SW
Unit 2518 lateral shear wall assembly, cantilevered entry canopy, and high-wall reinforced concrete side retaining structure along the west property line.
Cast-in-place concrete staircase and structural aluminum railing anchorage at 1612 25 Ave SW Calgary engineered by Tam-Crete
Unit 2518 cast-in-place concrete staircase, structural aluminum guardrail anchorage, and grade transition from street level (1091.80m) to main entry.
Construction & Execution Partner

Built & Executed by Tam-Building

While Tam-Crete Engineering delivered the structural engineering calculations, stepped foundation and retaining wall design, and P.Eng. stamped permit drawings for 1612 25 Ave SW (Units 2518 & 2520), full on-site construction and general contracting were completed by Tam-Building—trusted residential and multi-unit builders in Calgary.

Planning a Semi-Detached Infill or Sloping Lot Build in Calgary?

Partner with Tam-Crete Engineering for permit-ready APEGA P.Eng. stamped structural drawings, stepped concrete foundation and retaining wall design, drive-under garage transfer beams, and responsive field inspections across Calgary and Alberta.

✔ Permit Turnaround: Fast P.Eng. Stamped Drawings
✔ Direct Engineering Desk: Send Architectural Plans for Review →